The first stage of field experiments involving the design and construction of a low-power consumption ocean bottom electro-magnetometer (OBEM) has been completed, which can be deployed for more than 180 d on the seafloor with a time drift of less than 0.95 ppm. To improve the performance of the OBEM, we rigorously evaluated each of its units, e.g., the data loggers, acoustic parts, internal wirings, and magnetic and electric sensors, to eliminate unwanted events such as unrecovered or incomplete data. The first offshore deployment of the OBEM together with ocean bottom seismographs (OBSs) was performed in NE Taiwan, where the water depth is approximately 1400 m. The total intensity of the magnetic field (TMF) measured by the OBEM varied in the range of 44 100–44 150 nT, which corresponded to the proton magnetometer measurements. The daily variations in the magnetic field were recorded using the two horizontal components of the OBEM magnetic sensor. We found that the inclinations and magnetic data of the OBEM varied with two observed earthquakes when compared to the OBS data. The potential fields of the OBEM were slightly, but not obviously, affected by the earthquakes.
Marine electromagnetic exploration is a geophysical prospecting technique used to reveal the electrical resistivity features of the oceanic upper mantle down to depths of several hundreds of kilometers in different geologic and tectonic environments, such as in areas around mid-oceanic ridges, areas around hot-spot volcanoes, subduction zones, and normal ocean areas between mid-oceanic ridges and subduction zones (Ellis et al., 2008; Evans et al., 2005; Key, 2012; Utada, 2015).
Specifications of the OBEM compared to the Japanese OBEM and OBE (Kasaya and Goto, 2009).
Even though many magnetotelluric explorations have investigated deep electrical structures on Taiwan (Bertrand et al., 2009, 2012; Chiang et al., 2011, 2010, 2015, 2008), there were no marine electromagnetic experiments around Taiwan until 2010. The first generation of ocean bottom seismographs (OBSs) was developed by the Institute of Earth Sciences, Academia Sinica (IES), Taiwan Ocean Institute, National Applied Research Laboratories, and the Institute of Undersea Technology, National Sun Yat-sen University (OBS R&D team), in 2009, called Yardbird-20s. These OBSs have acquired large amounts of data via a series of deployments offshore Taiwan that can be used to study plate tectonics and crustal characteristics (Kuo et al., 2015, 2012, 2014). Subsequently, the OBS R&D team developed an ocean bottom electro-magnetometer (OBEM) modified from the OBS based on important developmental experiments.
The novel OBEM was constructed by the OBS R&D team and has completed the first stage of field experiments by the Institute of Earth Sciences, National Ocean Taiwan University, and IES. One OBEM and six broadband OBSs, called Yardbird-BBs (Broadband Yardbirds), were deployed at the western end of the Okinawa Trough (OT), NE Taiwan, for field testing in March 2018. The water depth in this area is approximately 1400 m. All the instruments were successfully recovered in May 2018 after collecting the first OBEM field data in Taiwan. Here, we introduce the OBEM design, specifications, calibration procedures, and its further developments and improvements.
A block diagram of the OBEM. The inputs of the two electric
fields, two inclinations and three magnetic fields pass through the Amp
& LPF in the data logger, which contains a 64 GB SD card. The SeaSCAN
time base module is integrated into the data logger and has a timing error
smaller than 3 s yr
The OBEM is designed to be wireless deep underwater equipment; however, the
power supply is limited for the wireless OBEM because the batteries cannot
be directly charged via electric cables from vessels. Therefore, designing
low-power consumption for the OBEM and high-efficiency battery packs is
critically required for long periods of operation. The major units of the
OBEM include a data logger, a magnetic sensor, a tiltmeter, electric
receivers with an arm-folding mechanism, a relocation system, recovery
units and an anchor. All the units for the OBEM use nonmagnetic materials
(e.g., the screws and anchor). Figure 1 shows a block diagram of the OBEM,
whereas the specifications of the OBEM compared to the Japanese system
(Kasaya and Goto, 2009) are shown in Table 1. We designed the data logger,
release mechanism and the OBEM platform to integrate all the sensors or
units purchased from related manufacturers and focused on the issues of
saving power and reducing costs. The detailed requirements of the OBEM are
listed below.
A magnetic sensor with three axes for measuring magnetic fields. A tiltmeter with two axes for measuring leveling changes to correct the tilt
error of the magnetic sensor. Two pairs of non-polarized electrodes with 2 m bendable arms with a total
distance between the electrodes of approximately 4.5 m. A highly accurate data logger with at least seven channels and a sampling rate of greater than or equal to 10 samples per second (SPS). Operation time of more than 180 d. An internal timing error of less than 3 s yr Acoustic relocation and recovery control systems. Power consumption of less than 1.5 W. A radio beacon, flush beacon, reflect label and orange flag for
identification on the sea surface during instrument recovery. A 0.75 m s A maximum deployment depth of more than 6000 m appropriate for most
seawater depths offshore Taiwan.
The solutions found for the OBEMs are listed below.
A fluxgate with three axes with a sensitivity of Four non-polarized electrodes (Ag A tiltmeter with two axes with inclinations of Two pairs of silver chloride electrodes with a 2 m arm-folding mechanism. A low-noise and low-power consumption eight-differential channel 24 bit A/D data logger with an accurate internal timing clock. Acoustic transponder and controller units. Radio beacon and flash beacon units. An OBEM platform modified from that of OBS. High-efficiency lithium battery packs for the sensors and data logger.
The OBEM is recovered by releasing its anchor from the seafloor via an
onboard acoustic command. The OBEM is returned to the sea surface via
buoyancy when the anchor is released. There are two typical release
mechanisms available for OBEMs to unlock their anchors: spin motor and
burn-wire systems (Kasaya and Goto, 2009). The OBEM uses the burn-wire
system because it weighs less than the spin motor system. The acoustic
controller and transducer use ORE #B980175 ASSY PCB and #D980709,
respectively, manufactured by EdgeTech, USA, for the corresponding functions
of OBEM recovery and underwater ranging. The ASSY PCB acoustic controller
uses a binary FSK (frequency-shift keying) encoder, including the commands “RELEASE1”,
“RELEASE2”, “DISABLE”, “ENABLE” and “OPTIONAL1”. The frequency of
the acoustic range ranges from 7.5 to 15 kHz in increments of 0.5 kHz
with a sensitivity of 80 dB re 1 V
The EdgeTech 8011M model acoustic commander (8011M) is used on board to send the ENABLE command to open the ranging function, the “RANGE” command to measure the distance between the OBEM and the research vessel, the DISABLE command to close the ranging function, and the RELEASE1 command to activate the burn-wire system to release the anchor. The RELEASE1 command persists for 15 min unless terminated by the OPTIONAL1 command.
A block diagram of the OBEM data logger. The ADS1278EVM is a 24 bit A/D with eight inputs used for converting analog signals via the amplifier and low-pass filter (Amp & LPF) to digital data. The Amp & LPF adjusts the output voltages of the sensors of the fluxgate, tiltmeter and electric receivers to suitable A/D input levels. The two MCUs of the MPS430F5436A process the timing synchronization by the SeaSCAN of time base and GPS modules, the digital data storage to the SD card with a standard SDHC, and the user interface communication with a PC.
We selected the RF-700A and ST-400A NOVATECH models for the radio and flash beacons, respectively, for use in the OBEM. The maximum deployment depth for these models is 7300 m. The radio beacon is turned ON by sending a VHF (very high-frequency) signal, and the flush beacon is turned ON at atmospheric pressure of less than 1 atm (equal to a depth of 10 m below the sea surface) in a dark environment. The beacons are also turned OFF at a depth of 10 m or at atmospheric pressure of less than 1 atm, respectively. These two beacons have four independently installed C-type alkaline batteries that allow for 6 d of continuous operation at a maximum; this power supply differs from that of the data logger. The two independent power supply layouts allow the beacons to properly operate even if the power supply for the data logger fails. An onboard radio scanner detects the signal transmitted from the radio beacon at a distance of 6.4–12.9 km when the OBEM is floating on the surface. These two beacons can assist in locating the OBEM on the sea surface in both daytime and nighttime.
TL-5930 model lithium batteries manufactured by TADIRAN are used for the
OBEM, with specifications of 3.6 V, 19 Ah and a D type, with characteristics
of high energy density and a low self-discharge rate suitable for long
periods of operation. Figure 2 shows a block diagram of the OBEM data
logger. The ADC1278EVM model is a 24 bit A/D converter used for the inputs
of the three fluxgate axes, the two tiltmeter axes and two pairs of
non-polarized electrodes with a sampling rate of 10 SPS. An amplifier and a
low-pass filter (Amp & LPF) were designed for the magnetic sensor,
leveling sensor and electric receiver inputs. The two MPS430F5436A
microcontrollers (MCUs) process the timing synchronization of the time base
manufactured by SeaSCAN, USA, and the GPS modules; the digital data are
stored on a Secure Digital (SD) memory card with a standard Secure Digital
High Capacity (SDHC), and the user interface communicates with a PC. The
time base module supplies a precise time base signal to the data logger,
whereas the SISMTB Ver 4.1 time base module generates a precise 125 Hz clock
that supports a timing error smaller than 3 s yr
Two 17 in. glass VITROVEX spheres manufactured by Nautilus Marine Service GmbH, Germany, are used for the OBEM. These glass spheres contain the fluxgate and tiltmeter (sensor ball) and the seven channels of the Amp & LPF, data logger, #B980175 ASSY PCB acoustic controller and batteries (instrument ball) and can be deployed at a depth of 6000 m and support a total buoyancy of 52 kg. The instrument and sensor balls, the silver chloride electrodes, and the burn-wire system are connected via waterproof cables. There is a pressure-vacuum valve outside the glass spheres that allows a pumped vacuum to be preserved at 0.7 atm; self-fusing butyl rubber tape is used to fill the suture zone between the half glass spheres. In addition, two crossed stainless-steel bands are used to improve the waterproofing of the glass spheres and cover the orange PE cases. Four PVC pipes with lengths of 2 m are combined to form the OBEM platform for the electric receivers, and the silver chloride electrodes are installed at the ends of the pipes. A 60 kg nonmagnetic anchor is attached to the bottom of the OBEM platform and catches via a releasing mechanism. The anchor can be released using the burn-wire system to recover the OBEM. Figure 3 shows a photograph of the OBEM platform.
A photograph of the OBEM01 and its specific modules.
It is necessary to calibrate each unit of the OBEM, including the data logger with the Amp & LPF, fluxgate, tiltmeter, electrodes, ASSY PCB acoustic controller, transducer and wiring, before and after assembling the OBEM to improve its performance. We describe the series of calibration methods used for the OBEM units in the following section.
The background noise of the data logger is defined as
Connect MX, MY, MZ, TX and TY to GND (Ground), EX Start the record mode of the data logger, wait for 60 s to acquire data, and then stop recording data. Download the data from the data logger and convert it to ASCII format. Then, calculate the background noise using Eq. (
The input ranges of the voltages for MX, MY and MZ are
Calibration results for the magnetic channels of the OBEM01.
Calibration results for the electric channels of the OBEM01.
Calibration results for the inclination channels of the OBEM01.
The layout for the evaluation of the electric receivers. Two
copper electrodes are used to vary the input signals. A pair of silver
chloride electrodes are placed at the corner of a tank with an area of 68 cm
The dynamic range is the ratio of the maximum count to the background noise.
It is defined as
Connect the MX, MY and MZ channels of the data logger to the source
voltages generated by the calibrator (FLUKE726) and connect the GND channel
of the data logger to the source common point (COM) of FLUKE726. Set the data logger to the recording mode. Set the FLUKE726 output voltages from 0 to Connect the TX and TY channels of the data logger to the source voltages generated by FLUKE726 and connect the GND channel of the data logger to the COM of FLUKE726. Set the FLUKE726 output voltages from 0 to Connect the EX Set the FLUKE726 output voltages from 0 to Finally, switch off the recording mode of the data logger, download the data and convert it to ASCII format for analysis. Calculate the
sensitivity, linearity error and dynamic range using Eqs. (3), (4) and (5), respectively.
Figure 4 shows a calibration of the magnetic channels (MX, MY and MZ)
checking the sensitivity, linearity and error. The average sensitivity is
655 968.5 counts V
The total current consumption of the OBEMs.
The power supplies of the OBEM consist of two 7.2 V battery packs in a
series connection with two 3.6 V lithium batteries. One battery pack is for
the data logger and converts to
Two pairs of silver chloride electrodes are used for the OBEM. We first put
a pair of electrodes separated by a fixed distance within a tank filled with
seawater to check the status of the electrodes. Second, we measured the
electrical potential and impedance of the electrodes using a digital
volt–ohm–milliammeter (VOM) (Fig. 7). Third, we sent a swept sine signal to
check the frequency responses of the electrodes, as shown in Fig. 8. Fourth,
we input a DC voltage to check the electrode-induced voltages, as shown in
Fig. 9. Table 3 shows the self-potential, impedance and induced voltages
for each pair of electrodes. The ranges of the self-potential and impedance
are 0.26–3.63 mV and 243–370
The responses of the electrodes with varying frequencies. The
response curves of
The self-potential, impedance and induced voltage results for each pair of silver chloride electrodes.
The fluxgate is mounted in the sensor ball of the OBEM. Therefore, we could
only calculate the total magnetic field (TMF) (Eq.
The responses of the electrodes with varying voltages. The input ranged from 500 to 2500 mVDC to check the induced voltage; the induced voltages are proportional to the input voltages.
We selected the large-scale Breeze Canal in New Taipei City for testing because it has few obstacles and is suitable for evaluating the functions of the 8011M. The Breeze Canal has a length of approximately 800 m and is located in a straight river with a depth of 2–5 m. The distance between the transducer and the acoustic transceiver was approximately 630 m, and the layout for the field test is shown in Fig. 10. The testing procedure for the transducers is described below. The results are listed in Table 4.
A map of the field test to evaluate the acoustic transducer,
acoustic controller and 8011M (modified from Google Maps,
Example results for the functional test of the acoustic transducer.
Example results for the functional test of the acoustic controller.
Connect the tested transducer and acoustic transceiver via an underwater cable, and place the tested transducer and transceiver at an underwater depth of 1 m. Record the serial numbers of the transducers in a notebook. Send the ENABLE command via the 8011M, and then count the response beeps. Send the RANGE command via the 8011M five times, and record the distance of each ranging. Send the DISABLE command via the 8011M, and then count the response beeps. Replace the transducer, and return to step 2 to repeat the evaluation.
A location map showing the Yardbird-BBs and OBEM with triangle and diamond symbols, respectively.
The OBEM01 time series data. The panels from top to bottom in the
figure show the four magnetic fields (
We then checked the acoustic transceivers after all of the transducers were
successfully checked; the testing procedure for the acoustic controller is
described below. The results are listed in Table 5.
Change the acoustic controller, and record its serial number in a
notebook. Send the ENABLE command via the 8011M, and then count the response beeps. Send the RANGE command via the 8011M five times, and record the
distance of each ranging. Send the RELEASE1 command via the 8011M, and then count the response beeps. Check the voltage between Pin1 and Pin2 of JP2 using a VOM. It should
be greater than 12.0 VDC. Send the “OPTION1” command via the 8011M, and then count the response beeps. Check the voltage between Pin1 and Pin2 of JP2 using a VOM. It should be 0 VDC. Send the RELEASE2 command via the 8011M, and then count the response beeps. Check the voltage between Pin3 and Pin4 of JP2 using a VOM. It should be greater than 12.0 VDC. Send the OPTION1 command via the 8011M, and then count the response beeps. Check the voltage between Pin3 and Pin4 of JP2 using a VOM. It should be 0 VDC. Send the DISABLE command via the 8011M, and then count the response beeps. Send the RANGE command via the 8011M; there should be no response from the transceiver. Return to step 1 to repeat the evaluation.
A mercury switch is mounted on the transceiver which when turned off responds with 15 beeps and when turned on responds with seven beeps.
Comparison of the OBEM01 and 1802OBS time series data during the two earthquakes. The two earthquakes affected the inclinations. The first and secondary earthquakes occurred at 12:41 and 12:47 UTC, respectively, on 27 April 2018. SH1 and SH2: two horizontal components of the seismic signal; SZ: vertical component of the seismic signal.
The variations in PGV, TMF, HY, TX and TY during the first
earthquake. The PGV of 2.63 cm s
We deployed six Yardbird-BBs and one OBEM near a small submarine volcano
area in the OT offshore NE Taiwan (Fig. 11) on 26 March 2018 for a submarine
observation to evaluate all the OBEM units. All the equipment was
successfully recovered after 1 month of deployment. Figure 12 shows the
time series of data of OBEM01. The TMF calculated from the three components
of the magnetic field varied in the range of 44 100–44 150 nT, which
corresponded to the geomagnetic field measured by proton magnetometers in
Taiwan. The two horizontal magnetic fields contained significant daily
variations. Furthermore, the vibrations of the inclinations were
significantly affected by two earthquakes on 27 April 2018 (at 12:41 and
12:47 UTC) consistent with seismic signals of the Yardbird-BBs (Fig. 13). The
average magnetic fields of HX, HY, HZ and TMF 2 s prior to the earthquakes
(12:41 UTC) were 12 900, 34 300, 24 600 and 44 137 nT,
respectively, the average potential fields of EX and EY were
We subtracted the background averages of the magnetic fields and the
inclinations to compare the differential during the 12:41 UTC event as shown
in Fig. 14. The peak ground motion velocity (PGV) was 2.63 cm s
A long-period OBEM acquisition platform to measure magnetic and electrical fields on the seafloor was successfully constructed and evaluated by the OBS R&D team for deployment offshore Taiwan. The power consumption of the OBEM is less than 1 W, which means that the lifetime could be extended up to 300 d with the installation of 108 lithium batteries. We deployed and recovered the OBEM at an underwater depth of 1400 m to acquire the first marine magnetotelluric data offshore NE Taiwan.
Six Yardbird-BBs and one OBEM were deployed near a small submarine volcano area offshore NE Taiwan. The TMF calculated from the three magnetic field components varied in the range of 44 100–44 150 nT, which corresponded to the proton magnetometer measurements of the geomagnetic field in Taiwan. The two horizontal magnetic fields displayed significant daily variations, and the vibrations of the inclinations were significantly affected by the two earthquakes that occurred during the observations. There was an insignificant amount of variation in the electric fields.
Localized microearthquakes affected the disturbances of the magnetic field and inclinations in this study. Therefore, to improve the efficacy of marine geophysical explorations, a platform for multiple underwater measurements is required including an ocean bottom flowmeter, thermometer and absolute pressure gage. We will focus on such developments, in which the evaluated results show that the data logger, flush and radio beacons, EMI filter, and an integrated junction board must be improved in relation to noise levels, cost and convenient maintenance issues in the future.
The data used in the paper can be accessed by contacting the corresponding author.
CRL and CWC wrote the paper with contributions from all authors. KYH primarily provided results on testing and characterizing OBEM performance. The OBEMs presented here were developed at the Taiwan Ocean Research Institute led by YHH under a contract from the National Ocean Taiwan University, Academia Sinica, the National Applied Research Laboratories and the National Taiwan University. PCC, HKC and JPJ designed, constructed, built, assembled and tested infrastructure at the Taiwan Ocean Research Institute used to characterize and document OBEM for this paper. KHC and FSL completed preliminary tests of the OBEM manufacturing process. SL and BYK primarily completed the literature review on the OBEM.
The authors declare that they have no conflict of interest.
We greatly appreciate the crews of R/V
This research has been supported by the MOST, TAIWAN (grant nos. 101-3113-P-002-013, 102-3113-P-002-005, 103-3113-M-002-004, 104-3113-M-002-004, 105-2116-M-019-001, 106-2116-M-001-008, 106-2116-M-019-003, 107-2116-M-019-006, 108-2116-M-001-012 and 108-2116-M-019-006).
This paper was edited by Valery Korepanov and reviewed by Kai Chen and Denghai Bai.