Calibration methods and results of the in-situ experiments on Cluster and Double Star
Calibration methods and results of the in-situ experiments on Cluster and Double Star
Editor(s): H. Laakso, C.-P. Escoubet, A. Masson, and M. Taylor
The Cluster Active Archive of ESA has invested a significant amount of resources in order to calibrate all high-resolution measurements collected by a large number of in-situ experiments on board Cluster and Double Star spacecraft. This is the first time that any space agency tries to do this. Therefore plenty of new in-flight calibration techniques have been developed in years, and plenty of new results on long-term evolution of calibration parameters have been obtained. Contributions from this area are invited to this special issue.

Download citations of all papers

01 Sep 2014
CLUSTER–STAFF search coil magnetometer calibration – comparisons with FGM
P. Robert, N. Cornilleau-Wehrlin, R. Piberne, Y. de Conchy, C. Lacombe, V. Bouzid, B. Grison, D. Alison, and P. Canu
Geosci. Instrum. Method. Data Syst., 3, 153–177, https://doi.org/10.5194/gi-3-153-2014,https://doi.org/10.5194/gi-3-153-2014, 2014
27 Aug 2014
In-flight calibration of double-probe electric field measurements on Cluster
Y. V. Khotyaintsev, P.-A. Lindqvist, C. M. Cully, A. I. Eriksson, and M. André
Geosci. Instrum. Method. Data Syst., 3, 143–151, https://doi.org/10.5194/gi-3-143-2014,https://doi.org/10.5194/gi-3-143-2014, 2014
11 Jul 2014
An initial investigation of the long-term trends in the fluxgate magnetometer (FGM) calibration parameters on the four Cluster spacecraft
L. N. S. Alconcel, P. Fox, P. Brown, T. M. Oddy, E. L. Lucek, and C. M. Carr
Geosci. Instrum. Method. Data Syst., 3, 95–109, https://doi.org/10.5194/gi-3-95-2014,https://doi.org/10.5194/gi-3-95-2014, 2014
05 May 2014
In-flight calibration of the Cluster PEACE sensors
N. Doss, A. N. Fazakerley, B. Mihaljčić, A. D. Lahiff, R. J. Wilson, D. Kataria, I. Rozum, G. Watson, and Y. Bogdanova
Geosci. Instrum. Method. Data Syst., 3, 59–70, https://doi.org/10.5194/gi-3-59-2014,https://doi.org/10.5194/gi-3-59-2014, 2014
23 Apr 2014
In-flight calibration of the Hot Ion Analyser on board Cluster
A. Blagau, I. Dandouras, A. Barthe, S. Brunato, G. Facskó, and V. Constantinescu
Geosci. Instrum. Method. Data Syst., 3, 49–58, https://doi.org/10.5194/gi-3-49-2014,https://doi.org/10.5194/gi-3-49-2014, 2014
16 Apr 2014
Background subtraction for the Cluster/CODIF plasma ion mass spectrometer
C. G. Mouikis, L. M. Kistler, G. Wang, and Y. Liu
Geosci. Instrum. Method. Data Syst., 3, 41–48, https://doi.org/10.5194/gi-3-41-2014,https://doi.org/10.5194/gi-3-41-2014, 2014
13 Feb 2014
Interpretation of Cluster WBD frequency conversion mode data
J. S. Pickett, I. W. Christopher, and D. L. Kirchner
Geosci. Instrum. Method. Data Syst., 3, 21–27, https://doi.org/10.5194/gi-3-21-2014,https://doi.org/10.5194/gi-3-21-2014, 2014
22 Jan 2014
Interinstrument calibration using magnetic field data from the flux-gate magnetometer (FGM) and electron drift instrument (EDI) onboard Cluster
R. Nakamura, F. Plaschke, R. Teubenbacher, L. Giner, W. Baumjohann, W. Magnes, M. Steller, R. B. Torbert, H. Vaith, M. Chutter, K.-H. Fornaçon, K.-H. Glassmeier, and C. Carr
Geosci. Instrum. Method. Data Syst., 3, 1–11, https://doi.org/10.5194/gi-3-1-2014,https://doi.org/10.5194/gi-3-1-2014, 2014
19 Dec 2013
Enhanced timing accuracy for Cluster data
K. H. Yearby, S. N. Walker, and M. A. Balikhin
Geosci. Instrum. Method. Data Syst., 2, 323–328, https://doi.org/10.5194/gi-2-323-2013,https://doi.org/10.5194/gi-2-323-2013, 2013
18 Nov 2013
Spectral analysis for wide energy channels
E. A. Kronberg and P. W. Daly
Geosci. Instrum. Method. Data Syst., 2, 257–261, https://doi.org/10.5194/gi-2-257-2013,https://doi.org/10.5194/gi-2-257-2013, 2013
10 Oct 2013
In-flight calibration of the Cluster/CODIF sensor
L. M. Kistler, C. G. Mouikis, and K. J. Genestreti
Geosci. Instrum. Method. Data Syst., 2, 225–235, https://doi.org/10.5194/gi-2-225-2013,https://doi.org/10.5194/gi-2-225-2013, 2013
CC BY 4.0