The effect of winding and core support material on the thermal gain dependence of a fluxgate magnetometer sensor

David M. Miles, Ian R. Mann, Andy Kale, David K. Milling, Barry B. Narod, John R. Bennest, David Barona, and Martyn J. Unsworth

Download

Interactive discussion

Status: closed
Status: closed
AC: Author comment | RC: Referee comment | SC: Short comment | EC: Editor comment
Printer-friendly Version - Printer-friendly version Supplement - Supplement
Download
Short summary
Fluxgate magnetometers are an important geophysical tool but are typically sensitive to changes in sensor temperature. We used a novel, low-cost calibration procedure to compare six matched sensors in which the material used as the mechanical support is varied and found that 30 % glass-filled PEEK engineering plastic is a good candidate for sensors. It is more economical, easier to machine, lighter, and more robust than historically used machinable ceramic.