Contributors to fluxgate magnetic noise in permalloy foils including a potential new copper alloy regime
Department of Physics and Astronomy, University of Iowa, Iowa City, IA 52242, USA
Richard Dvorsky
Department of Physics and Astronomy, University of Iowa, Iowa City, IA 52242, USA
Kenton Greene
Department of Physics and Astronomy, University of Iowa, Iowa City, IA 52242, USA
Christian T. Hansen
Department of Physics and Astronomy, University of Iowa, Iowa City, IA 52242, USA
B. Barry Narod
Department of Earth, Ocean and Atmospheric Sciences, University of British Columbia, Vancouver, Canada
Michael D. Webb
Department of Physics and Astronomy, University of Iowa, Iowa City, IA 52242, USA
Related authors
Matthew G. Finley, Allison M. Flores, Katherine J. Morris, Robert M. Broadfoot, Sam Hisel, Jason Homann, Chris Piker, Ananya Sen Gupta, and David M. Miles
Geosci. Instrum. Method. Data Syst., 13, 263–275, https://doi.org/10.5194/gi-13-263-2024, https://doi.org/10.5194/gi-13-263-2024, 2024
Short summary
Short summary
Spaceflight magnetic-field measurements are often contaminated by interference from the host spacecraft. We present a new dataset to enable the development and testing of interference mitigation schemes for spaceflight magnetic-field data. Over 100 h of data, including laboratory-generated proxies for magnetic interference and geophysical signals, have been produced. A ground truth for the underlying interference is also provided, enabling the rigorous quantification of data-cleaning techniques.
Kenton Greene, Scott R. Bounds, Robert M. Broadfoot, Connor Feltman, Samuel J. Hisel, Ryan M. Kraus, Amanda Lasko, Antonio Washington, and David M. Miles
Geosci. Instrum. Method. Data Syst., 13, 249–262, https://doi.org/10.5194/gi-13-249-2024, https://doi.org/10.5194/gi-13-249-2024, 2024
Short summary
Short summary
Demonstrating the space flight capability of the next generation of precise, reliable magnetic field instruments is important for enabling future space science missions that will further our understanding of the connection between Earth's magnetic field and the Sun. Here, we present a new magnetic field instrument design called Tesseract, the results from its successful first space flight demonstration aboard a rocket, and its measurements of magnetic fields associated with the aurora.
B. Barry Narod and David M. Miles
Geosci. Instrum. Method. Data Syst., 13, 131–161, https://doi.org/10.5194/gi-13-131-2024, https://doi.org/10.5194/gi-13-131-2024, 2024
Short summary
Short summary
We present the experimental results of a new copper-based alloy suitable for use in high-precision magnetic sensing. It outperforms by providing lower magnetic noise and superior power consumption. Prototype sensors constructed from this material can meet an exacting standard, the 2012 1 s INTERMAGNET standard, for magnetic observatories.
Cole J. Dorman, Chris Piker, and David M. Miles
Geosci. Instrum. Method. Data Syst., 13, 43–50, https://doi.org/10.5194/gi-13-43-2024, https://doi.org/10.5194/gi-13-43-2024, 2024
Short summary
Short summary
Magnetic field measurements in space can be contaminated by stray magnetic fields from their host satellite. We present an automated tool for measuring the magnetic field generated by potential satellite and instrument components to identify those that may degrade the measurements taken on orbit. This tool is designed for use by the Tandem Reconnection and Cusp Electrodynamics Reconnaissance Satellites (TRACERS) Small Explorers mission and is currently being used for mission design activities.
Robert M. Broadfoot, David M. Miles, Warren Holley, and Andrew D. Howarth
Geosci. Instrum. Method. Data Syst., 11, 323–333, https://doi.org/10.5194/gi-11-323-2022, https://doi.org/10.5194/gi-11-323-2022, 2022
Short summary
Short summary
The Swarm-Echo Satellite carries two magnetometers that allow us to obtain two independent measurements of the changes that occur in the Earth's magnetic field during events such as aurora. Magnetometers must be independently calibrated to ensure they remain accurate. If no magnetic reference is available, a model magnetic field must be used. This paper discusses the method used to calibrate the magnetometers on Swarm-Echo and shows the improvements the calibration has made to the data product.
Kenton Greene, Christian Hansen, B. Barry Narod, Richard Dvorsky, and David M. Miles
Geosci. Instrum. Method. Data Syst., 11, 307–321, https://doi.org/10.5194/gi-11-307-2022, https://doi.org/10.5194/gi-11-307-2022, 2022
Short summary
Short summary
The ability to make reliable magnetic measurements in space is very important for a broad range of applications in space science. Here, we present the design and performance of a new magnetometer that looks very promising for making stable reliable magnetic measurements in space. We show that Tesseract performs better than the traditional ring-core design in metrics that are associated with stability.
Matthew G. Finley, Allison M. Flores, Katherine J. Morris, Robert M. Broadfoot, Sam Hisel, Jason Homann, Chris Piker, Ananya Sen Gupta, and David M. Miles
Geosci. Instrum. Method. Data Syst., 13, 263–275, https://doi.org/10.5194/gi-13-263-2024, https://doi.org/10.5194/gi-13-263-2024, 2024
Short summary
Short summary
Spaceflight magnetic-field measurements are often contaminated by interference from the host spacecraft. We present a new dataset to enable the development and testing of interference mitigation schemes for spaceflight magnetic-field data. Over 100 h of data, including laboratory-generated proxies for magnetic interference and geophysical signals, have been produced. A ground truth for the underlying interference is also provided, enabling the rigorous quantification of data-cleaning techniques.
Kenton Greene, Scott R. Bounds, Robert M. Broadfoot, Connor Feltman, Samuel J. Hisel, Ryan M. Kraus, Amanda Lasko, Antonio Washington, and David M. Miles
Geosci. Instrum. Method. Data Syst., 13, 249–262, https://doi.org/10.5194/gi-13-249-2024, https://doi.org/10.5194/gi-13-249-2024, 2024
Short summary
Short summary
Demonstrating the space flight capability of the next generation of precise, reliable magnetic field instruments is important for enabling future space science missions that will further our understanding of the connection between Earth's magnetic field and the Sun. Here, we present a new magnetic field instrument design called Tesseract, the results from its successful first space flight demonstration aboard a rocket, and its measurements of magnetic fields associated with the aurora.
B. Barry Narod and David M. Miles
Geosci. Instrum. Method. Data Syst., 13, 131–161, https://doi.org/10.5194/gi-13-131-2024, https://doi.org/10.5194/gi-13-131-2024, 2024
Short summary
Short summary
We present the experimental results of a new copper-based alloy suitable for use in high-precision magnetic sensing. It outperforms by providing lower magnetic noise and superior power consumption. Prototype sensors constructed from this material can meet an exacting standard, the 2012 1 s INTERMAGNET standard, for magnetic observatories.
Cole J. Dorman, Chris Piker, and David M. Miles
Geosci. Instrum. Method. Data Syst., 13, 43–50, https://doi.org/10.5194/gi-13-43-2024, https://doi.org/10.5194/gi-13-43-2024, 2024
Short summary
Short summary
Magnetic field measurements in space can be contaminated by stray magnetic fields from their host satellite. We present an automated tool for measuring the magnetic field generated by potential satellite and instrument components to identify those that may degrade the measurements taken on orbit. This tool is designed for use by the Tandem Reconnection and Cusp Electrodynamics Reconnaissance Satellites (TRACERS) Small Explorers mission and is currently being used for mission design activities.
Robert M. Broadfoot, David M. Miles, Warren Holley, and Andrew D. Howarth
Geosci. Instrum. Method. Data Syst., 11, 323–333, https://doi.org/10.5194/gi-11-323-2022, https://doi.org/10.5194/gi-11-323-2022, 2022
Short summary
Short summary
The Swarm-Echo Satellite carries two magnetometers that allow us to obtain two independent measurements of the changes that occur in the Earth's magnetic field during events such as aurora. Magnetometers must be independently calibrated to ensure they remain accurate. If no magnetic reference is available, a model magnetic field must be used. This paper discusses the method used to calibrate the magnetometers on Swarm-Echo and shows the improvements the calibration has made to the data product.
Kenton Greene, Christian Hansen, B. Barry Narod, Richard Dvorsky, and David M. Miles
Geosci. Instrum. Method. Data Syst., 11, 307–321, https://doi.org/10.5194/gi-11-307-2022, https://doi.org/10.5194/gi-11-307-2022, 2022
Short summary
Short summary
The ability to make reliable magnetic measurements in space is very important for a broad range of applications in space science. Here, we present the design and performance of a new magnetometer that looks very promising for making stable reliable magnetic measurements in space. We show that Tesseract performs better than the traditional ring-core design in metrics that are associated with stability.
Cited articles
Abrams, H.:
Grain size measurement by the intercept method,
Metallography,
4, 59–78, https://doi.org/10.1016/0026-0800(71)90005-X, 1971.
Couderchon, G., Porteseil, J. L., Bertotti, G., Fiorillo, F., and Soardo, G. P.:
Magnetization process in NiFe alloys with vanishing anisotropies,
IEEE T. Magn.,
25, 3973–3975, 1989.
English, A. T. and Chin, G. Y.:
Metallurgy and magnetic properties control in permalloy,
J. Appl. Phys.,
38, 1183–1187, 1967.
Fornacon, K.-H., Auster, H. U., Georgescu, E., Baumjohann, W., Glassmeier, K.-H., Haerendel, G., Rustenbach, J., and Dunlop, M.:
The magnetic field experiment onboard Equator-S and its scientific possibilities,
Ann. Geophys.,
17, 1521–1527, https://doi.org/10.1007/s00585-999-1521-3, 1999.
Gordon, D., Lundsten, R., and Chiarodo, R.:
Factors affecting the sensitivity of gamma-level ring-core magnetometers,
IEEE T. Magn.,
1, 330–337, https://doi.org/10.1109/TMAG.1965.1062987, 1965.
Gordon, D., Lundsten, R., Chiarodo, R., and Helms, H.:
A fluxgate sensor of high stability for low field magnetometry,
IEEE T. Magn.,
4, 397–401, 1968.
Hinnrichs, C., Pels, C., and Schilling, M.:
Noise and linearity of a fluxgate magnetometer in racetrack geometry,
J. Appl. Phys.,
87, 7085–7087, https://doi.org/10.1063/1.372939, 2000.
Hinnrichs, C., Stahl, J., Kuchenbrandt, K., and Schilling, M.:
Dependence of sensitivity and noise of fluxgate sensors on racetrack geometry,
IEEE T. Magn.,
37, 1983–1985, https://doi.org/10.1109/20.951028, 2001.
Janosek, M.:
Parallel Fluxgate Magnetometers,
in: High Sensitivity Magnetometers,
edited by: Grosz, A., Haji-Sheikh, M. J., and Mukhopadhyay, S. C.,
Springer International Publishing, Cham, 41–61, https://doi.org/10.1007/978-3-319-34070-8_2, 2017.
Meister, S.:
grain and particle analysis with line intersection method, MATLAB Central File Exchange, https://www.mathworks.com/matlabcentral/fileexchange/35203-grain-and-particle-analysis-with-line-intersection-method (last access: 1 March 2022), 2020.
Miles, D. M., Ciurzynski, M., Barona, D., Narod, B. B., Bennest, J. R., Kale, A., Lessard, M., Milling, D. K., Larson, J., and Mann, I. R.: Low-noise permalloy ring cores for fluxgate magnetometers, Geosci. Instrum. Method. Data Syst., 8, 227–240, https://doi.org/10.5194/gi-8-227-2019, 2019.
Moldovanu, C., Brauer, P., Nielsen, O. V., and Petersen, J. R.:
The noise of the Vacquier type sensors referred to changes of the sensor geometrical dimensions,
Sensor. Actuat. A-Phys.,
81, 197–199, https://doi.org/10.1016/S0924-4247(99)00087-4, 2000.
Müller, M., Lederer, T., Fornacon, K. H., and Schäfer, R.:
Grain structure, coercivity and high-frequency noise in soft magnetic Fe-81Ni-6Mo alloys,
J. Magn. Magn. Mater.,
177, 231–232, 1998.
Musmann, G.:
Fluxgate magnetometers for space research, BoD–Books on Demand, 2010.
Narod, B. B.: The origin of noise and magnetic hysteresis in crystalline permalloy ring-core fluxgate sensors, Geosci. Instrum. Method. Data Syst., 3, 201–210, https://doi.org/10.5194/gi-3-201-2014, 2014.
Narod, B. B., Bennest, J. R., Strom-Olsen, J. O., Nezil, F., and Dunlap, R. A.: An evaluation of the noise performance of Fe, Co, Si, and B amorphous alloys in ring-core fluxgate magnetometers, Can. J. Phys., 63, 1468–1472, 1985.
Odani, Y.:
Magnetic Properties of Cube-Textured 6-81.3 Mo – Permalloy,
J. Appl. Phys.,
35, 865–866, 1964.
Pfeifer, F.:
Zum Verständnis der magnetischen Eigenschaften technischer Permalloylegierungen,
Z. Met.,
57, 295, 1966.
Pfeifer, F. and Boll, R.:
New soft magnetic alloys for applications in modern electrotechnics and electronics,
IEEE T. Magn.,
5, 365–370, 1969.
Primdahl, F.:
The fluxgate magnetometer,
J. Phys. E Sci. Instrum., 12, 241, 1979.
Ripka, P.:
Improved fluxgate for compasses and position sensors,
J. Magn. Magn. Mater.,
83, 543–544, https://doi.org/10.1016/0304-8853(90)90618-Z, 1990.
Ripka, P.:
Race-track fluxgate sensors,
Sensor. Actuat. A-Phys.,
37–38, 417–421, https://doi.org/10.1016/0924-4247(93)80071-N, 1993.
Ripka, P.:
Race-track fluxgate with adjustable feedthrough,
Sensor. Actuat. A-Phys.,
85, 227–231, https://doi.org/10.1016/S0924-4247(00)00394-0, 2000.
Scanlon, W. W.:
Solid state research of the Applied Physics Department for the year 1965,
Naval Ordnance Lab, White Oak, MD, 1966.
Scarzello, J. F., Holmes, J. J., and O'keefe, E. C.:
Integrating fluxgate magnetometer, US Department of Navy, United States patent US 6,278,272, 2001.
Sene, F. F. and Motta, C. C.:
Synthesis and characterization of Ni-Mo filler brazing alloy for Mo-W joining for microwave tube technology,
Mater. Res.,
16, 417–423, https://doi.org/10.1590/S1516-14392013005000019, 2013.
Snare, R. C.:
A History of Vector Magnetometry in Space,
in: Measurement Techniques in Space Plasmas Fields,
edited by: Pfaff, R. F., Borovsky, J. E., and Young, D. T.,
American Geophysical Union, 101–114, https://doi.org/10.1002/9781118664391.ch12, 1998.
Turbitt, C., Matzka, J., Rasson, J., St-Louis, B., and Stewart, D.:
An instrument performance and data quality standard for intermagnet one-second data exchange,
in: Proceedings of the XVth IAGA Workshop on Geomagnetic Observatory Instruments, Data Acquisition, and Processing, XVth IAGA Workshop on Geomagnetic Observatory Instruments and Data Processing, 4–14 June 2012, Cadiz, Spain, 186–188, 2013.
von Auwers, O. and Neumann, H.:
Über Eisen–Nickel–Kupfer-Legierungen hoher Anfangspermeabilität,
Spec. Print. Sci. Publ. Siemens-Fact.,
XIV, 92–108, 1935.
Wallis, D. D., Miles, D. M., Narod, B. B., Bennest, J. R., Murphy, K. R., Mann, I. R., and Yau, A. W.:
The CASSIOPE/e-POP Magnetic Field Instrument (MGF),
Space Sci. Rev.,
189, 27–39, https://doi.org/10.1007/s11214-014-0105-z, 2015.
Short summary
We present an experiment intended to enable extremely low-noise magnetic field measurements. We manufactured fluxgate magnetometer cores using two metal alloys, two geometries, two foil thicknesses, and six different heat treatments and compared the resulting material properties, power consumption, and magnetic noise. Our results suggest that thinner foils, potentially using a new copper alloy, manufactured into continuous racetrack washers may provide excellent performance in fluxgate sensors.
We present an experiment intended to enable extremely low-noise magnetic field measurements. We...