Articles | Volume 6, issue 2
https://doi.org/10.5194/gi-6-495-2017
https://doi.org/10.5194/gi-6-495-2017
Research article
 | 
21 Nov 2017
Research article |  | 21 Nov 2017

Development of a full-waveform voltage and current recording device for multichannel transient electromagnetic transmitters

Xinyue Zhang, Qisheng Zhang, Meng Wang, Qiang Kong, Shengquan Zhang, Ruihao He, Shenghui Liu, Shuhan Li, and Zhenzhong Yuan

Related authors

Method for processing XCP data with improved accuracy
Xinyue Zhang, Qisheng Zhang, Xiao Zhao, Qimao Zhang, Shenghui Liu, Shuhan Li, and Zhenzhong Yuan
Geosci. Instrum. Method. Data Syst., 6, 209–215, https://doi.org/10.5194/gi-6-209-2017,https://doi.org/10.5194/gi-6-209-2017, 2017
Short summary

Related subject area

Ground-based instruments
Development of an internet-of-things-based controlled-source ultrasonic audio frequency electromagnetic receiver
Zucan Lin, Qisheng Zhang, Keyu Zhou, Xiyuan Zhang, Xinchang Wang, Hui Zhang, and Feng Liu
Geosci. Instrum. Method. Data Syst., 13, 325–336, https://doi.org/10.5194/gi-13-325-2024,https://doi.org/10.5194/gi-13-325-2024, 2024
Short summary
Distance of flight of cosmic-ray muons to study dynamics of the upper muosphere
Hiroyuki Tanaka
Geosci. Instrum. Method. Data Syst. Discuss., https://doi.org/10.5194/gi-2024-4,https://doi.org/10.5194/gi-2024-4, 2024
Revised manuscript accepted for GI
Short summary
A tool for estimating ground-based InSAR acquisition characteristics prior to monitoring installation and survey and its differences from satellite InSAR
Charlotte Wolff, Marc-Henri Derron, Carlo Rivolta, and Michel Jaboyedoff
Geosci. Instrum. Method. Data Syst., 13, 225–248, https://doi.org/10.5194/gi-13-225-2024,https://doi.org/10.5194/gi-13-225-2024, 2024
Short summary
An underground drip water monitoring network to characterize rainfall recharge of groundwater at different geologies, environments, and climates across Australia
Andy Baker, Margaret Shanafield, Wendy Timms, Martin Sogaard Andersen, Stacey Priestley, and Marilu Melo Zurita
Geosci. Instrum. Method. Data Syst., 13, 117–129, https://doi.org/10.5194/gi-13-117-2024,https://doi.org/10.5194/gi-13-117-2024, 2024
Short summary
Research and application of a flexible measuring array for deep displacement of landslides
Yang Li, Zhong Li, Qifeng Guo, Yimin Liu, and Daji Zhang
Geosci. Instrum. Method. Data Syst., 13, 97–105, https://doi.org/10.5194/gi-13-97-2024,https://doi.org/10.5194/gi-13-97-2024, 2024
Short summary

Cited articles

Analog Devices Incorporated: AD9226 datasheet, Analog Devices Incorporated, USA, 2001.
Boris, M. and Bernhard, E. B.: A 12-bit 75-MS/s Pipelined ADC Using Open-Loop Residue Amplification, IEEE J. Solid-State Circuits, 12, 2040–2050, 2003.
Huang, Y. W., Yan, J. H., and Zhou, W.: Data Acquisition Test System Based on FPGA, Modern Radar, 37, 73–76, 2015.
Jhin, F. H., Jin, Y. W., and Cheng, K. H.: An 8-bit 20 MS/s Successive Approximation Register Analog-to-digital Converter with Low Input Capacitance, Int. J. Eng. Pract. Res., 4, 83–88, 2014.
Jia, H. Y., Chen, G. C., and Zhang, H.: A new structure of substage in pipelined analog-to-digital converters, The Journal of China Universities of Posts and Telecommunications, 16, 86–90, 2009.
Download
Short summary
We believe that our study full-waveform voltage and current recording device for MTEM transmitters makes a significant contribution to the literature because this full-waveform recording device can be used to monitor the high-power, full-waveform voltages and currents of MTEM transmitters. It has high precision, finer edge details, low noise, and other advantages. Hence, it can be used for real-time recording and transmission to the receiver for coherent demodulation.