Articles | Volume 6, issue 2
https://doi.org/10.5194/gi-6-361-2017
https://doi.org/10.5194/gi-6-361-2017
Research article
 | 
25 Sep 2017
Research article |  | 25 Sep 2017

In situ vector calibration of magnetic observatories

Alexandre Gonsette, Jean Rasson, and François Humbled

Related authors

Fog-based automatic true north detection for absolute magnetic declination measurement
Alexandre Gonsette, Jean Rasson, Stephan Bracke, Antoine Poncelet, Olivier Hendrickx, and François Humbled
Geosci. Instrum. Method. Data Syst., 6, 439–446, https://doi.org/10.5194/gi-6-439-2017,https://doi.org/10.5194/gi-6-439-2017, 2017
Short summary
An automatic DI-flux at the Livingston Island geomagnetic observatory, Antarctica: requirements and lessons learned
Santiago Marsal, Juan José Curto, Joan Miquel Torta, Alexandre Gonsette, Vicent Favà, Jean Rasson, Miquel Ibañez, and Òscar Cid
Geosci. Instrum. Method. Data Syst., 6, 269–277, https://doi.org/10.5194/gi-6-269-2017,https://doi.org/10.5194/gi-6-269-2017, 2017
Short summary

Related subject area

Ground-based instruments
A tool for estimating ground-based InSAR acquisition characteristics prior to monitoring installation and survey and its differences from satellite InSAR
Charlotte Wolff, Marc-Henri Derron, Carlo Rivolta, and Michel Jaboyedoff
Geosci. Instrum. Method. Data Syst., 13, 225–248, https://doi.org/10.5194/gi-13-225-2024,https://doi.org/10.5194/gi-13-225-2024, 2024
Short summary
An underground drip water monitoring network to characterize rainfall recharge of groundwater at different geologies, environments, and climates across Australia
Andy Baker, Margaret Shanafield, Wendy Timms, Martin Sogaard Andersen, Stacey Priestley, and Marilu Melo Zurita
Geosci. Instrum. Method. Data Syst., 13, 117–129, https://doi.org/10.5194/gi-13-117-2024,https://doi.org/10.5194/gi-13-117-2024, 2024
Short summary
Research and application of a flexible measuring array for deep displacement of landslides
Yang Li, Zhong Li, Qifeng Guo, Yimin Liu, and Daji Zhang
Geosci. Instrum. Method. Data Syst., 13, 97–105, https://doi.org/10.5194/gi-13-97-2024,https://doi.org/10.5194/gi-13-97-2024, 2024
Short summary
A hydrate reservoir renovation device and its application in nitrogen bubble fracturing
Jingsheng Lu, Yuanxin Yao, Dongliang Li, Jinhai Yang, Deqing Liang, Yiqun Zhang, Decai Lin, and Kunlin Ma
Geosci. Instrum. Method. Data Syst., 13, 75–83, https://doi.org/10.5194/gi-13-75-2024,https://doi.org/10.5194/gi-13-75-2024, 2024
Short summary
Gas equilibrium membrane inlet mass spectrometry (GE-MIMS) for water at high pressure
Matthias S. Brennwald, Antonio P. Rinaldi, Jocelyn Gisiger, Alba Zappone, and Rolf Kipfer
Geosci. Instrum. Method. Data Syst., 13, 1–8, https://doi.org/10.5194/gi-13-1-2024,https://doi.org/10.5194/gi-13-1-2024, 2024
Short summary

Cited articles

Alldregde, L. R.: A proposed Automatic Standard Magnetic Observatory, J. Geophys. Res., 65, https://doi.org/10.1029/JZ065i011p03777, 1960.
Eckstaller, A., Müller, C., Ceranna, L., and Hartmann, G.: The geophysics observatory at Neumayer stations (GvN and NM-II) Antarctica, Polarforschung, 76, 3–24, 2007.
Gonsette, A., Rasson, J., and Marin, J.-L.: Autodif: Automatic Absolute DI Measurements, Proceeding of the XVth IAGA Workshop on Geomagnetic Observatory Instruments, data Acquisition and Processing, 2012.
Gonsette, A., Rasson, J., Bracke, S., Poncelet, A., Hendrickx, O., and Humbled, F.: Automatic True North detection during absolute magnetic declination measurement, Geosci. Instrum. Method. Data Syst. Discuss., https://doi.org/10.5194/gi-2017-18, in review, 2017.
Download
Short summary
We present a novel method for calibrating magnetic observatories. We show how magnetometer baselines can highlight a possible calibration error. We also provide a method based on high-frequency automatic absolute measurements. This method determines a transformation matrix for correcting raw data suffering from scale factor and orientation errors. We finally present a practical case where covered data have been successfully compared to those coming from a reference magnetometer.